40
/40
Forward : test 1 GND() , Sus-out()
2 Sus-out(),Vs()
3 ER-DN(),ER-COM()
4 ER-COM(),ER-UP()
when each 4 TEST Diode value is over 0.4V => OK
Reverse : test 1 GND() , Sus-out()
2 Sus-out(),Vs()
3 ER-DN(),ER-COM()
4 ER-COM(),ER-UP()
when each 4 nodes TEST Diode value is infinity => OK
Specially, the value of ER-UP,COM,DN in the Y/Z board, should be
checked all of them. but, the terminal of Vs,Sus-out,GND,
we must aware to know after check one of IPM because it is parallel.
Æ if no problems, check 15V(Y,Z B/D) with GND, Î Forward value 0.3V,
Reverse value infinite. If no problems,
4. Trouble shooting.
How to check IPM