Issued Date: September 18, 2003
Model No.: V270W - L03
Approval
Note (7) Measurement Setup:
The LCD module should be stabilized at given temperature for 1 hour to avoid abrupt
temperature change during measuring. In order to stabilize the luminance, the measurement
should be executed after lighting Backlight for 1 hour in a windless room.
Light Shield Room
(Ambient Luminance < 2 lux)
Display Color Analyzer
(Minolta CA210)
Center of the Screen
LCD Panel
LCD Module
Note (8) Definition of White Variation (δW):
Measure the luminance of gray level 255 at 5 points
δW = Maximum [L (1), L (2), L (3), L (4), L (5)] / Minimum [L (1), L (2), L (3), L (4), L (5)]
Horizontal Line
X
3W/4
W/2
W/4
3D/4D/2D/4
43
21
5
: Test Point
X=1 to 5
W
D
Vertical Line
Active Area
20 / 26
The information described in this technical specification is tentative and it is possible to be changed without prior