MPC500 Operator's Manual rev 1.0
Initialize To Factory Default
Various Sample and Sequence settings can be saved to Compact Flash when the file is saved. The global settings found in the MPC500
(listed below) are saved to the internal Flash Memory and stored when the MPC500 is turned off. You can re-initialize the Factory Preset
settings using the following procedure.
1. Turn the MPC500 on while holding the [ERASE / UNDO] button.
2. Release the [ERASE / UNDO] button after the display shows [MPC500 (##MB installed)].
Now the MPC500 is reset to the Factory Preset settings. The following global settings are stored in the MPC500:
Timing Correct (Note value, Swing%)
Click/Metronome (Count in, Rate, In play, In rec)
Step Edit Options (Auto step increment, Duration of recorded notes)
Active track receive channel
Soft thru
Sync in
Sync out
Master level
Sustain pedal to duration
Truncate dura
Tap average
Autoload
Version
The MPC 2500’s operating system is upgradeable and allows us make changes to existing features after it has left the factory floor. To
make sure you have the latest version of the OS, you can check the version of the OS in Other mode.
To confirm you have the latest operating system, check the support section of http://www.akaipro.com
.
How to Upgrade the MPC500
IMPORTANT: THIS UPDATE PROCEDURE WILL ERASE ALL USER DATA. Please save all of your songs, patterns, and samples to a
CF card or to your computer using USB before proceeding.
1. Save the new OS file from the website to the ROOT of the CF card using your computer.
2. Insert the CF with OS data into MPC500.
3. Turn the power on while holding down the [SHIFT] button.
4. When prompted by the display, press the REC button. The MPC500 will start the update procedure.
5. Because of all the new features and parameters, it will be necessary to re-initialize the MPC500 after the upgrade
procedure is complete. To do so, turn the MPC500 off, hold down the Erase button, and turn the unit back on.