Chapter 3: Recording Sequences
Page 29
• The Active Tempo field (BPM:120.0
(SEQ) in the above example):
This is the active playing tempo. If the sequence contains tempo
changes, this shows the active tempo at the current sequence position
displayed in the Now field.
• The Tempo Source field (BPM:120.0 (SEQ)
in the above example):
This is a choice field with two options:
1. SEQ (sequence): Within each sequence is a unique tempo
setting. If this option is selected, the sequence’s unique
tempo is used in the Active Tempo field. In this case,
whenever the active sequence number is changed, the newly
selected sequence’s tempo immediately appears in the Active
Tempo field. When playing sequences, this is useful if you
want each newly selected sequence to play at its own preset
tempo. The sequence’s tempo is saved to disk when a
sequence is saved.
2. MAS (master): The master tempo is a single tempo setting
that applies to all sequences and songs. When playing
sequences this is useful if you always want each newly
selected sequence to play at the same tempo. This tempo
setting is not saved in the sequence file.
• The Time Signature field (Sig: 4/ 4
in the above example):
This field shows the time signature of the current bar (displayed in the
Now field) of the active sequence. It is for display only and cannot be
changed. For information on how to change the time signature of a bar
or to insert time signature changes, see the “Editing Sequences”
chapter of this manual.
• The Bars field:
This shows the total number of bars in the active sequence. It is for
display only and cannot be changed.
• The Loop field:
This is a choice field with two options:
1. OFF:
If this option is selected, the sequence stops playing when it
reaches its end. However, if in Record mode, recording
continues past the end, adding one measure (with the time
signature of the last bar) onto the end of the sequence as
each new bar is entered, until the sequence is stopped.
2. TO BAR 1:
If this option is selected, when the sequence plays to the end,
it immediately loops back to the bar number displayed to the
right of the word BAR. To set the number of the bar to which
the sequence loops back, move the cursor to the field to the
right of the word BAR and enter the new number.
COMMENT: If the bar to loop to is bar number 1 and the
sequence is in Record mode, the MPC60 will automatically
Vue de la page 34